Ref. No. : 55388599   
Company Name : Can be viewed by Subscribers
Product Detail : Tender For Drawing Of Electrical Main Cable Line In 3rd Floor , 2nd Floor And 1st Floor And Ground Floor Of The New Building From Electrical Raising Main Installed At The Rear Side Of The New Building Of The Society ( At 1 Park Street, Kolkata -70016) With Electrical Accessories, Supplying And Fixing Following Ways Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcb's, With Provision Of 160 Amps Tp 16 Ka Mccb As Incomer, Interconnection Between Incomer Mccb And Bus Bars (but Without Mcb's/ Mccb) As Required . (note Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.), 4 Way (4 + 12), Double Door, 6 Way (4 + 18), Double Door, 8 Way (4 + 24), Double Door, Providing And Fixing Following Rating And Breaking Capacity Fp Mccb In Existing Vtpn Mcb Db Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required., 125amp, Tpn, 16ka,With Thermal Magnetic Protection, Providing And Fixing Following Rating And Breaking Capacity Fp Mccb In Existing Vtpn Mcb Db Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required., 100amp, Tpn, 16ka,With Thermal Magnetic Protection, Supplying And Fixing Following Rating, Triple Pole,415 Volts, "c" Curve Mcb In The Existing Vtpn Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required., 63 Amps Tripple Pole, Supplying And Fixing 6-32 Amps Rating, Single Pole, 240 Volts, "c" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Tpn Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required., 32 Amp Single Pole, Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required, 4 X16 Sq. Mm.+ 2 X 6 Sq. Mm Earth Wire, Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required, Supplying And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Aluminium Armour Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required., 3.5 Core X 50 Sq. Mm., Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required, 3.5 Core X 50 Sq. Mm., Dismantling Of Existing Outdated/Damaged Old Industrial Type Distribution Panel Including Dismantling Of Connections Of Lt Cable And Other Accessories Etc. As Required., Providing And Fixing 6 Swg G.I. Wire On Surface Or Recess For Loop Earthing As Requied., Supplying And Fixing Following Ways Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcb's, With Provision Of 160 Amps Tp 16 Ka Mccb As Incomer, Interconnection Between Incomer Mccb And Bus Bars (but Without Mcb's/ Mccb) As Required . (note Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.), 6 Way (4 + 18), Double Door, 8 Way (4 + 24), Double Door, Providing And Fixing Following Rating And Breaking Capacity Fp Mccb In Existing Vtpn Mcb Db Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required., 125amp, Tpn, 16ka,With Thermal Magnetic Protection, Supplying And Fixing Following Rating, Triple Pole,415 Volts, "c" Curve Mcb In The Existing Vtpn Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required., 63 Amps Tripple Pole, Supplying And Fixing 6-32 Amps Rating, Single Pole, 240 Volts, "c" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Tpn Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required., 32 Amp Single Pole, Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required, 4 X 16 Sq. Mm. + 2 X 6 Sq. Mm, Supplying And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Aluminium Armour Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required., 3.5 Core X 50 Sq. Mm., Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required, 3.5 Core X 50 Sq. Mm., Dismantling Of Existing Outdated/Damaged Old Industrial Type Distribution Panel Including Dismantling Of Connections Of Lt Cable And Other Accessories Etc. As Required., Providing And Fixing 6 Swg G.I. Wi
Tender Location : West Bengal - India
Document Path : Can be viewed by Subscribers
Tender EMD : INR 20000
Tender Closing Date : 3/01/2023 at 00:00 Hrs.
Tender Opening Date : 4/01/2023 at 00:00 Hrs.
Sub-Industry/Industry : Corporations/ Assoc/ Chambers/ Govt Agencies - Non-financial Services   
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Industry
Skip Navigation Links.
Expand Electrical TendersElectrical Tenders
more  »
Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders
 Tenders by State in India
Andhra Pradesh Tenders
Delhi Tenders
Gujarat Tenders
Madhya Pradesh Tenders
Maharashtra Tenders
Rajasthan Tenders
Tamil Nadu Tenders
Uttar Pradesh Tenders
West Bengal Tenders
more  »